The Promoda Incoming Feeder Vacuum Circuit Breaker (VCB) Switchgear Panel is a metal-clad medium voltage feeder panel designed to control and protect incoming power supply lines in industrial substations, captive power plants, and utility distribution systems.
Serving as the primary interface between the upstream power source and the internal distribution network, this panel ensures safe incoming power control, fault isolation, and protection for downstream electrical equipment. The switchgear integrates a high-performance withdrawable vacuum circuit breaker capable of interrupting high fault currents and maintaining stable switching performance under heavy electrical loads.
Designed with a fully compartmentalized metal-clad construction, the panel separates high-voltage components such as the circuit breaker, busbars, cable terminations, and control equipment into independent sections. This architecture improves operational safety and simplifies maintenance by preventing fault propagation across compartments.
The withdrawable breaker truck allows the circuit breaker to move safely between service, test, and isolated positions, enabling inspection and functional testing without disconnecting power cables. This significantly reduces maintenance downtime and improves operational efficiency in industrial environments.
Manufactured with precision sheet-metal fabrication, high-conductivity copper busbars, and maintenance-free vacuum interrupters, the panel is suitable for medium voltage systems ranging from 3.3 kV to 33 kV. The switchgear complies with IEC 62271-200 for metal-enclosed switchgear and IEC 62271-100 for circuit breakers, ensuring reliable and safe operation in critical power distribution systems.
Incoming feeder VCB panels are widely used in industrial substations, utility distribution networks, and infrastructure power systems where secure incoming power control and system protection are essential.
Designed to manage and protect the incoming supply line of medium voltage substations.
Vacuum circuit breaker ensures reliable interruption of high fault currents.
Breaker truck supports service, test, and isolated positions for safe inspection and maintenance.
Improves operational safety and electrical isolation.
Manufactured according to IEC 62271-200 and IEC 62271-100 standards.
Engineered for continuous operation in demanding industrial power environments.
The incoming feeder switchgear panel incorporates a metal-clad compartmentalized architecture designed to improve safety and maintenance accessibility.
| Parameter | Specification |
|---|---|
| Voltage Range | 3.3 kV – 33 kV |
| Rated Current | Up to 3150 A |
| Short Circuit Breaking Capacity | Up to 40 kA |
| Short Time Withstand Current | Up to 40 kA for 3 seconds |
| Circuit Breaker Type | Withdrawable Vacuum Circuit Breaker |
| Internal Arc Classification | AFL / AFLR as per IEC 62271-200 |
| Operating Mechanism | Stored Energy Spring Mechanism |
| Panel Construction | Metal-clad, compartmentalized switchgear |
| Ingress Protection | IP42 / IP54 |
| Panel Height | Approx. 2200 mm |
| Control Wiring | FRLS copper wiring, ferruled and numbered |
| Applicable Standards | IEC 62271-100, IEC 62271-200 |